Shure Microflex® MX400SE Series microphones are miniature gooseneck-mounted electret condenser microphones designed for speech and vocal pickup. Their high sensitivity and broad frequency range make them suitable for recording, as well as sound reinforcement applications.

MX400SE microphones can be screwed onto a mic stand or the supplied 5/8 inch 27-threaded flange. They can be easily changed from side-exit to bottom-exit to conceal the cable. All models include an in-line preamplifier and a 3 m (10 ft) cable. Each microphone is available with interchangeable cardioid, supercardioid, or omnidirectional cartridges.

View all Audio Rentals >>
View Video Rentals >>
View Lighting Rentals >>

  • Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
  • Interchangeable cartridges provide the right polar pattern for every application
  • Balanced, transformerless output for increased immunity to electromagnetic hum and RF interference over long cable runs
  • Shock mount provides over 20 dB isolation from surface vibration noise
  • Locking flange mount for permanently securing microphone to lecterns, pulpits, or conference tables
  • Snap-fit foam windscreen
  • Supplied shock mount for more than 20 dB isolation from surface transmitted noise
  • Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table
Frequency Response 50 to 17,000 Hz
Output Impedance (at 1000 Hz) Rated at150 Ω (180 Ω actual)
Open Circuit Sensitivity (at 1 kHz, ref. 1 V/Pascal*)
*(1 Pascal= 94 dB SPL)
Cardioid: -35.0 dB (17.8 mV)
Supercardioid: -33.5 dB (21.1 mV)
Omnidirectional: -27.5dB (42.2 mV)
Maximum SPL (1 kHz at 1% THD, 1 kO load) Cardioid: 124.2.0 dB
Supercardioid: 122.7 dB
Omnidirectional: 116.7 dB
Equivalent Output Noise (A-weighted) Cardioid: 28.0 dB SPL
Supercardioid: 26.5 dB SPL
Omnidirectional: 20.5 dB SPL
Signal to Noise Ratio (referenced at 94 dB SPL) Cardioid: 66.0 dB
Supercardioid: 67.5 dB
Omnidirectional: 73.5 dB
Dynamic Range at 1 kO Load 96.2 dB
Common Mode Rejection 45.0 dB minimum
Preamplifier Output Clipping Level (1% THD) -6.0 dBV (0.5 V)
Polarity Positive sound pressure on diaphragm produces positive
voltage on pin 2 relative to pin 3 of output connector.
Power Requirements 11 to 52 Vdc phantom, 2.0 mA